(Message sent via IEEE Standards webmail) ----------------------------------------- Commenter = Lu Yang Affiliation = RITT, CATR SenderEmail = luyang@ritt.cn SenderPhone = +86-13661386633 StandardRev = IEEE Std 1904.1-2013 SubclauseNumber = 14.2.2.6 Page = 453 Rationale = The range of sub-attribute aOnuConfigTimeDrift.sHoldOverPeriod is defined as 0-65536, which means holdover timer is set to 65s. This will never happen in EPON system. ProposedChange = Change the Range of sHoldOverPeriod to:0x00-32 (50) to 0x03-E8 (1000) Impact = No impact on existing networks. ----------------------------------------- (End of IEEE Standards webmail message)