(Message sent via IEEE Standards webmail) ----------------------------------------- Commenter = Glen Kramer Affiliation = Broadcom SenderEmail = gkramer@broadcom.com SenderPhone = (707)529-0917 StandardRev = IEEE Std 1904.1-2013 SubclauseNumber = 14.4.5.6.5 Page = 658 Rationale = Units for the action acLaserTxPowerOff (0xD9/0x06-05) should be milliseconds, not seconds. In DPoE 1.0, the units were ms, but inadvertently changed to seconds in DPoE2.0. There has been an ECR submitted against DPoE2.0 to change the units back to ms. SIEPON Package A should align to the new unit value as well. Using units of milliseconds is a more reasonable approach. It will allow operators to implement automatic troubleshooting methods, where a laser in each ONU can be shut down for a few milliseconds without affecting services. For a manual operation, laser still can be shut down until explicitly enabled. ProposedChange = Change unit of acLaserTxPowerOff (0xD9/0x06-05) action from 1 second to 1 millisecond. Impact = Changes the expected behavior of acLaserTxPowerOff action, but shall not result in network operation issues. ----------------------------------------- (End of IEEE Standards webmail message)